Design of slurry piping systems should follow ANSI/ASME B31.1 and B31.11 Codes. A simple equation for this calculation is as follows: t = (PD) / (2S) + C where: t = pipe wall thickness, in. P = maximum design pressure of the pipe, psig S = maximum allowable design stress, psig C = corrosion or erosion allowance, in.