Answers

Question and Answer:

  Home  Chemical Engineering

⟩ How can one quickly estimate the additional pressure drop to be introduced with more tube passes?

When the calculated pressure drop inside the tubes is underutilized, the estimated pressure drop with increased number of tube passes is new tube DP = DP x (NPASS/OPASS)3 Where NPASS = New number of tube passes. OPASS = Old number of tube passes this would be a good estimate if advantage is not taken of the increase in heat transfer. Since the increased number of tube passes gives a higher velocity and increases the calculated heat transfer coefficient, the number of tubes to be used will decrease. Fewer tubes increase the new pressure drop. For a better estimate of the new pressure drop, add 25% if the heat transfer is all sensible heat. Source: Gulley Computer Associates

 214 views