1⟩ Explain the methods for starting an induction motor?
The different methods of starting an induction motor:
a) DOL:direct online starter
b) Star delta starter
c) Auto transformer starter
d) Resistance starter
e) Series reactor starter
“Generator Operator related Frequently Asked Questions in various Generator Operator job interviews by interviewer. The set of questions here ensures that you offer a perfect answer posed to you. So get preparation for your new job hunting”
The different methods of starting an induction motor:
a) DOL:direct online starter
b) Star delta starter
c) Auto transformer starter
d) Resistance starter
e) Series reactor starter
Safety in this profession is very important for every worker working inside the plant. A small mistake can lead to a big hazard and hence every minor chance of a mistake should be taken seriously.
N2, N3, fuel flow, oil pressure, oil temperature, oil quantity and engine vibration. FCOM 1 70.20.1
Literature...But where this factor needs to be mastered, then there is no way back down.
An electric generator is a machine that converts mechanical energy into electrical energy. An electric generator is based on the principle that whenever flux is cut by a conductor, an e.m.f. is induced which will cause a current to flow if the conductor circuit is closed. The direction of induced e.m.f. (and hence current) is given by Fleming’s right hand rule.
The losses in a d.c. machine (generator or motor) may be divided into three types
1. Copper losses: These losses occur due to currents in the various windings of the machine.
2. Iron or core losses: These losses occur in the armature of a d.c. machine and are due to the rotation of armature in the magnetic field of the poles. They are of two types
a. Hysteresis loss: Hysteresis loss occurs in the armature of the d.c. machine since any given part of the armature is subjected to magnetic field reversals as it passes under successive poles.
b. Eddy current loss: The voltages induced in the armature conductors produce circulating currents in the armature core known as eddy currents and power loss due to their flow is called eddy current loss. The eddy current loss appears as heat which raises the temperature of the machine and lowers its efficiency.
3. Mechanical losses: These losses are due to friction and windage. These losses depend upon the speed of the machine. But for a given speed, they are practically constant.
If their is high power factor, i.e if the power factor is close to one:
a)Losses in form of heat will be reduced,
b)Cable becomes less bulky and easy to carry, and very cheap to afford, &
c)It also reduces over heating of tranformers.
Two major types of Control Systems are
1) Open loop Control System
2) Closed Loop Control Systems
Open loop Control Systems:The Open loop Control System is one in which the Output Quantity has no effect on the Input Quantity. No feedback is present from the output quantity to the input quantity for correction.
Closed Loop Control System:The Closed loop Control System is one in which the feedback is provided from the Output quantity to the input quantity for the correction so as to maintain the desired output of the system.
It is used with generators for charging a number of capacitor in parallel and discharging them in series.It is used when voltage required for testing is higher than the available.
It reduces the harmonics and it also reduces sparking and arching across the mechanical switch so that it reduces the voltage spike seen in a inductive load.
1. Continuity of service
2. Efficiency
3. Maintenance and Repair
4. Increasing plant capacity
5. Non availability of single large unit
Armature reaction is the effect of magnetic field setup by armature current on the distribution of flux under main poles of a generator. The armature magnetic field has two effects
a. It demagnetizes or weakens the main flux
b. It cross-magnetizes or distorts it.
The first effect leads to reduced generated voltage and second to the sparking at the brushes.
Generators are generally classified based on their methods of field excitation
(i) Separately excited d.c. generators
(ii) Self-excited d.c. generators
To find a better job (more income), also to get more knowledge and widen my experience.
I was given the to complete the water wash of compressor in 24 hrs with desired valve of conductivity. I worked continuously 20 hours to achieve.
Steam a bowl of saturated temperature.
If actual thrust is less than commanded thrust during takeoff with airspeed between 65kts and V1-6kts. FCOM 1 70.20.16
Say them that you think positive under stress which fills some energy in you and that's how you face problems.
A power plant operator is a person who operates a power plant. He has got to be good at the technical skills of using the power plant and must be equally talented in distributing the work to the other workers who are working with the power plant.