41⟩ The purpose of a bonding conductor is to provide
* a) An earth fault path
* b) An equal potential zone
* c) Short circuit protection
* d) Overload protection
Answer – b
“Electrical engineering interview questions and answers, referred to as electrical and electronic engineering, Electrical Engineering interview questions and answers guide deals with the study and application of electricity, electronics and electromagnetism. The field interview questions and answers first became an identifiable occupation in the late nineteenth century after commercialization of electric telegraph and electrical power supply. Learn Electrical Engineering by interview questions”
* a) An earth fault path
* b) An equal potential zone
* c) Short circuit protection
* d) Overload protection
Answer – b
* a) 1, 3, 2, 4, 5
* b) 1, 2, 3, 4, 5
* c) 2, 1, 4, 3, 5
* d) 2, 3, 1, 4, 5
Answer – a
* a) 25 V between live conductors
* b) 55 V to earth
* c) 110 V to earth
* d) 12 V SELV
Answer – b
* a) Identify
* b) Evaluate
* c) Record
* d) Implement
* e) Review
Answer – b
* a) 13.08 Watts
* b) 196.2 Watts
* c) 392.4 Watts
* d) 1200 Watts
Answer – a
* a) Company sales representative
* b) Manufacturers’ manual
* c) Manufacturers’ catalogue
* d) Circuit diagram
Answer – b
* a) conductor
* b) Insulation
* c) Conductor
* d) Sheath
Answer – d
* a) V = _I_P
* b) V = P I
* c) V = P - I
* d) V = _P_I
Answer – d
* a) Warning sign
* b) Safety barrier
* c) Temporary bollard
* d) Audible warning device
Answer – b
* a) 0.8 O
* b) 1.25 O
* c) 29 O
* d) 400 O
Answer – a
* a) 2.08V
* b) 9.07V
* c) 11.14V
* d) 69V
Answer – b
* a) Normal conditions then automatically switch off after three hours
* b) Any power failure for up to three hours
* c) Both normal and power failure conditions then automatically switch off after three hours
* d) Power failures that last longer than three hours but not shorter than three hours
Answer – b
* a) TN-C-S
* b) TN-S
* c) TT
* d) IT
Answer – a
* a) short circuit conditions only
* b) Both earth fault and short circuit conditions
* c) Earth fault conditions only
* d) Overload conditions only
Answer – c
* a) Plumb line
* b) Spirit level
* c) Steel tape
* d) Chalk line
Answer – d
* a) 47
* b) 48
* c) 49
* d) 50
Answer – b
* a) Continuity of protective conductors, continuity of ring final circuits, insulation, - resistance and polarity
* b) Continuity of ring final circuits, insulation resistance, polarity, and earth fault loop - impedance
* c) Insulation resistance, polarity, earth fault loop impedance and continuity of protective - conductors
* d) Polarity, earth fault loop-impedance, continuity of protective conductors and Continuity of ring final circuits
Answer – a
* a) Stroboscopic effect
* b) Robotic effect
* c) Rotor effect
* d) Telescopic effect
Answer – a
* a) 230V
* b) 400V
* c) 33kV
* d) 400kV
Answer – d
* a) Voltage is present
* b) The voltage exceeds 230V and such voltage would not be expected
* c) The voltage exceeds 400V
* d) The voltage is below 230V
Answer – b