61⟩ Once a low-pressure mercury vapour lamp has lit, the purpose of the choke/ballast unit is to
* a) Discharge voltage
* b) Correct power factor
* c) Suppress radio interference
* d) Limit lamp current
Answer – d
“Electrical engineering interview questions and answers, referred to as electrical and electronic engineering, Electrical Engineering interview questions and answers guide deals with the study and application of electricity, electronics and electromagnetism. The field interview questions and answers first became an identifiable occupation in the late nineteenth century after commercialization of electric telegraph and electrical power supply. Learn Electrical Engineering by interview questions”
* a) Discharge voltage
* b) Correct power factor
* c) Suppress radio interference
* d) Limit lamp current
Answer – d
* a) Phase currents
* b) Earth faults
* c) Neutral currents
* d) Overloads
Answer – c
* a) Block diagram
* b) Layout drawing
* c) Circuit diagram
* d) Bar chart
Answer – a
* a) Current transformers and photoelectrical control units
* b) Voltage transformers and RCD’s
* c) Igniters and transformers
* d) Power factor meter and isolators
Answer – c
* a) The Laying of Cables in Public Highways
* b) H.S.E guidance H.S.G 47 (Avoiding danger from underground and overhead services)
* c) The Personal Protective Equipment at Work Regulations
* d) Electricity Association G39/1
Answer – c
* a) Throwing in a skip
* b) Putting in a glass recycle point (clear glass only)
* c) Using a suitable lamp crusher
* d) Putting in the refuse bins, which are collected weekly?
Answer – c
* a) The New Roads and Street Works Act
* b) The Electricity Safety, Quality, and Continuity Regulations 2002
* c) BS 7671
* d) The Electrical Equipment (Safety) Regulations
Answer – c
* a) Reduces the life of the lamp
* b) Could cause burns
* c) Generates excessive heat
* d) Lengthens lampworking life
Answer – a
* a) BS 7671 Requirements for Electrical Installation
* b) IEE Guidance Note 3 Inspection and testing
* c) IEE Code of Practice for In-Service Inspection and Testing of Electrical Equipment
* d) IEE on Site Guide
Answer – c
* a) It cannot read very small variations
* b) The direction of the deflection depends upon the direction of the current
* c) It is non linear
* d) It does not use the damping effect
Answer – b
* a) In the event of a fault current
* b) Under load conditions
* c) Under overload conditions
* d) Automatically after a fault has been repaired
Answer – b
* a) Must comply with BS 7671
* b) Are used to prove the circuit dead only
* c) Are used to prove the circuit was alive only
* d) Must be “proved” prior to and “re-proved” after isolation
Answer – d
* a) Pin
* b) Lug
* c) Insulation displacement
* d) Screw
Answer – c
* a) Eddy current damping
* b) Air damping
* c) Ambient temperature
* d) Operating temperature
Answer – c
* a) 601
* b) 712
* c) 413
* d) 314
Answer – b
* a) High temperature
* b) Dust and fibers
* c) Moisture ingress
* d) Day light
Answer – d
* a) BS EN 60439-01
* b) BS 4491
* c) BS 4444
* d) BS EN 60898
Answer – c
* a) Has a very low resistance
* b) Has a very high resistance
* c) Is connected in series with the supply
* d) Is connected in series with the load
Answer – b
* a) Circuit design current
* b) Physical space around terminations
* c) Presence of solid foreign bodies
* d) Size of conductor
Answer – c
* a) BS 7430
* b) Manufacturer’s catalogues
* c) GS 38
* d) Data charts
Answer – d